| Testing & Calibration EMI /EMC |
The EMI/EMC laboratory of AED accredited as per ISO 17025 is offering its evaluation testing services to the auto component, auto electronics, embedded & IT industry in the following areas:
Radiated Immunity
| |
As per test standards 95/54/EC, 2004/104/EC, ECE R-10, ISO 11452 etc. |
 |
| ALSE Chamber |
|
| |
Different test methods available viz. Free Field method in ALSE chamber (ISO 11452-2), TEM Cell method (ISO 11452-3), BCI method (ISO 11452-4), 150 mm Stripline method (ISO 11452-5) |
| |
Electromagnetic field up to 100 V/m with different modulation like AM, FM, Pulse |
| |
Frequency range of 10 kHz-2000 MHz |
| |
The system allows video/audio as well as status monitoring of EUT for performance verification. |
Radiated / Conducted Emission
| |
As per CISPR, ECE R-10, 95/54/EC, 2004/104/EC, etc. |
 |
| EMI Test Receiver |
|
| |
Frequency range : 150 kHz to 3000 MHz |
| |
QP, Peak, Average detector measurements |
| |
Tests performed in ALSE Chamber/OATS |
| |
|
Conducted Immunity and Transient Emissions
| |
As per Test Standards such as ISO 7637, SAE J1113, SAE 1455, manufacturer specific standards, etc. |
Electrostatic Discharge (ESD)
| |
As per Test Standard ISO:10605 and IEC 61000 4-2 |
| |
±30 kV Contact and Air Discharge |
| |
Various RC combinations for discharge gun as per standards |
EMI/EMC Testing of Industrial Electronic Systems
| |
IEC 61000-4-3, Radiated Immunity |
 |
| Scan Tool |
|
| |
IEC 61000-4-4, (EFT)Burst on power line |
| |
IEC 61000-4-4, (EFT) Burst on signal line-capacitive coupling clamp |
| |
IEC 61000-4-5, Surge on power line |
| |
IEC 61000-4-11, Power fail simulation |
| |
IEC 61000-4-8, Power frequency (50Hz) magnetic field |
| |
IEC 61000-4-6, Conducted disturbances induced by radio frequency fields, CDN, EM clamp |
The EMI/EMC laboratory has established "EMC PRECISION SCAN SYSTEM", a completely new engineering tool which provides near field measurements for printed circuit boards, and other electronic parts and wirings thus taking care of EMI problems at the design stage itself.
Key Words : EMI/EMC Testing, Electrostatic Discharge (ESD), Automotive EMC, Transient Emissions, Radiated Immunity, Radiated Emission, Conducted Immunity, Conducted Emission, Standard CISPR / ISO / ECE / SAE, BCI (Bulk Current Injection)
|
|