| Test Facility for
Evaluation Testing of Electronic
Components and Sub-systems |
Radiated Emission Test
| |
Frequency Range: 9 kHz – 3000 MHz |
 |
| |
Test Standards: CISPR 25, ECE R-10, 95/54/EC, 2004/104/EC etc. |
| |
Test Equipment:
| |
Absorber Lined Shielded Enclosure (ALSE) having size 7m x 6m x 4m along with shielded control room |
| |
Rohde and Schwarz, Germany make EMI Test Receiver 20 Hz – 8 GHz |
| |
Monopole Rod Antenna 9kHz – 30 MHz |
| |
Bi-conical Antenna 25 – 300 MHz |
| |
Log-periodic Antenna 200 – 3000 MHz |
|
| |
Broadband and Narrowband measurements with Peak, Quasi-Peak and Average detectors |
|
| |
Chamber ambient meets CISPR 25 class 5 stringent requirements |
|
Radiated Immunity Test
Free Field Method
| |
Frequency Range: 80 – 2500 MHz |
 |
| |
Test Standards: 95/54/EC, 2004/104/EC, ECE R-10, ISO 11452-2, IEC 61000-4-3 etc. |
| |
Test Equipment:
| |
Absorber Lined Shielded Enclosure (ALSE) having size 7m x 6m x 4m along with shielded control room |
| |
RF instrumentation such as signal generator, power meter, power amplifier, directional coupler, isotropic field probe etc. |
| |
Broadband biconilog antenna 30 – 3000 MHz |
|
| |
Electromagnetic field up to 100 V/m with different modulation like AM, FM, Pulse |
|
| |
Video/audio as well as status monitoring of EUT for performance verification |
Radiated Immunity Test
TEM Cell Method
| |
Frequency Range: 9 kHz – 200 MHz |
 |
| |
Test Standards: 95/54/EC, 2004/104/EC, ECE R-10, ISO 11452-3 etc. |
| |
Test Equipment:
| |
GTEM Cell |
| |
RF instrumentation such as signal generator, power meter, power amplifier, directional coupler, isotropic field probe etc. |
|
| |
Electromagnetic field up to 100 V/m with different modulation like AM, FM, Pulse |
|
| |
Video and status monitoring of EUT for performance verification |
|
| |
Maximum EUT size: 0.6m x 0.6m x 0.4m |
|
Radiated Immunity Test
Strip Line Method
| |
FrequencyRange: 9 kHz – 400 MHz |
 |
| |
Test Standards:ISO 11452-4, SAE J1113/4 etc. |
| |
Test Equipment:
| |
Compact equipment consisting of RF instrumentation such as signal generator, power meter, power amplifier, directional coupler etc. |
| |
Current clamps for RF injection and feedback |
|
| |
RF current up to 150 mA with AM modulation can be injected into the wiring harness of EUT |
|
Radiated Immunity Test
Bulk Current Injection (BCI) Method
| |
Frequency Range: 15 kHz – 1 GHz |
 |
| |
Test Standards: ISO 11452-5 |
| |
Test Equipment:
| |
150 mm strip line mounted on test table having size 430 x 150 x 105 cm |
| |
RF instrumentation such as signal generator, power meter, power amplifier, directional coupler, isotropic field probe etc. |
|
| |
Electromagnetic field up to 400 V/m with AM modulation can be generated |
|
Conducted Emission Test
| |
Frequency Range: 150 kHz – 108 MHz |
 |
| |
Test Standards: CISPR 25, SAE J1113 etc. |
| |
Test Equipment:
| |
Absorber Lined Shielded Enclosure (ALSE) having size 7m x 6m x 4m along with shielded control room |
| |
Rohde and Schwarz, Germany make EMI Test Receiver 20 Hz – 8 GHz |
| |
Line Impedance Stabilisation Network (LISN) for supply and ground lines. |
|
Conducted Immunity & Transient Emission Test
On Supply Lines
| |
Test Standards: ISO 7637, SAE J1113, SAE J1455, GM, Ford, Chrysler, Renault, Fiat, Daimler standards etc. |
 |
| |
Test Equipment:
| |
60 VDC, 16 A power supply simulating battery |
| |
Transient generators for micro pulses, electronic fast transients, power fail simulation, load dump |
| |
Artificial Network switch for transient emission test |
|
Electrostatic Discharge (ESD) Test
| |
Test Standards: ISO 10605, IEC 61000-4-2 etc. |
 |
| |
Test Equipment:
| |
+ 30 kV ESD generator with discharge gun |
| |
Separate gun tips for air and contact discharge |
| |
Different RC combinations 150 pF//330 ohm, 150 pF// 2 kohm, 330 pF// 2 kohm |
|
EMI/EMC Testing of Industrial Electronic Systems
| |
Test Standards: ISO 10605, IEC 61000-4-2 etc.
| |
IEC 61000-4-2, ESD |
| |
IEC 61000-4-3, Radiated Immunity |
| |
IEC 61000-4-4, (EFT) Burst on power line |
| |
IEC 61000-4-4, (EFT) Burst on signal line-capacitive coupling |
| |
IEC 61000-4-5, Surge on power line |
| |
IEC 61000-4-6, Conducted disturbances induced by radio frequency fields |
| |
IEC 61000-4-8, Power frequency (50Hz) magnetic field |
| |
IEC 61000-4-11, Power fail simulation |
|
 |
| |
Test Equipment: Burst generator, surge generator, motorized variac, magnetic field loop antenna, continuous wave generator, coupling clamp, ESD generator etc. |
|
EMI Scan Tool
| |
Application: Near field measurements for printed circuit boards, other electronic parts and wirings thus taking care of EMI problems at the design stage itself |
 |
| |
Frequency Range: 150 kHz – 3000 MHz |
| |
Scanning Area: 300 x 350 mm |
| |
Scanning Resolution: 1mm x 1mm |
| |
Scanning Method: Using XY positioning of micro-electromagnetic probe |
| |
Scan Analysis: Using spectrum analyser |
|
| |
Scan Presentation: Frequency spectrum data for each probe position plotted in 2D/3D viewing format superimposed on PCB image |
|
Combined Temperature & Vibration Test
| |
Specifications:
| |
Environmental Temperature Chamber: -40°C to 180°C, 10-95% RH |
| |
Vibration Shaker: 3 Axis, 1000 kgf, Sine/Random |
| |
Combined Operation in z-axis only |
| |
Max. EUT Size: 1m x 1m x 1m |
|
 |
Cyclic Temperature & Humidity Test
| |
Specifications:
| |
Temp & Humidity Range : -40°C to 180°C, 20-95% RH |
| |
Max. temp gradient 5°C/min |
| |
Max. EUT size: 0.6m x 0.45m x 0.75m |
|
 |
Altitude Test
| |
Specifications:
| |
Atmospheric Pressure Variation Range: 650 to 1150 mbar |
 |
| |
Equivalent altitude simulation up to 3000 m above mean sea level |
| |
Max. EUT size: 1m x 1m x 1m |
|
Thermal Shock Test
| |
Specifications:
| |
Hot Chamber: +20 °C to +220 °C |
 |
| |
Cold Chamber: -80 °C to +40 °C |
| |
Basket Transfer Time < 10 s |
| |
Test Standards : IS, DIN, IEC, MIL, JASO |
|
|
|
|
|
|
|
|