Universal
Chassis Dynamometer
|
|
|
Burke E Porter, USA make Universal Chassis
Dynamometer suitable for 2,3 and 4 wheeler vehicles with maximum power of 150
kW and inertia simulation upto 4000 kg.
|
| |
|
|
Dilute
Exhaust Emission Analysis System
|
| |
Pierburg, Germany make Dilute Exhaust Emission
Analysis System with capability of measuring exhaust emission concentrations of
CO, HC, NOx, CO2 for development emission testing of automotive vehicles on the
chassis dynamometer.
|
| |
|
|
|
|
| |
Environmental Temperature Chamber: 40 to
180°C, 10-95% RH Vibration Shaker: 3 Axis, 1000 kgf, Sine/Random Combined
Operation in z-axis only
|
| |
|
|
Thermal Shock Test facility
|
| |
Specifications:
|
| |
Hot Chamber: +20 °C to +220 °C,
|
| |
Cold Chamber: -80 °C to +40 °C,
|
| |
Basket Transfer Time < 10 s
|
| |
Test Standards:
|
| |
IS, DIN, IEC, MIL, JASO
|
| |
Radiated
Immunity
|
| |
The
relevant standards are 95/54/EC, ECE R-10, ISO 11452 etc.
|
 |
| |
GTEM
(TEM cell up to 2 GHz) Cell radiated immunity test facility.
|
| |
Electromagnetic
field up to 100 V/m over with different modulation like AM,
FM, Pulse.
|
| |
Frequency
range of 10 kHz-2000 MHz.
|
| |
The
system allows video as well as status monitoring of EUT for performance
verification.
|
| |
Radiated /Conducted Emission test facility
|
| |

As per CISPR, ECE R-10, 95/54/EC etc
|
| |

Rohde and Schwarz, Germany make EMI Test Receiver
|
| |

The vehicle test is performed on Open Area Test Site (OATS)
|
| |

For the component test, GTEM (Gigahertz Transverse Electromagnetic) Cell
|
| |

Proposed facility-ALSE chamber as per CISPR 25
|
| |
|
|
| |
Standards
are ISO 7637, SAE J1113, SAE 1455, manufacturer specific standards, etc.
|
 |
|
|
| |
Standards-
ISO 11452-4, SAE J1113/4, etc.
|
 |
| |
Non-invasive,
the probe can be simply clipped over any cable. No direct connection in mode to
any cable conductor.
|
| |
Specific
equipment per standard used for testing to ensure proper
testing and repeatability.
|
| |
|
|
|
|

Standard IEC 61000 4-2
|
|
|

+/- 8 kV Contact Discharge, +/- 16 kV Air Discharge.
|
|
|

Humidity and Temperature controlled rooms and lab.
|
|
|

Waveform verification with 1 GHz Oscilloscope.
|
| |
Other Related Services
|
|
|

IEC 61000-4-3, Radiated Immunity
|
|
|

ISO 7637 Series (-1, 2, 3) Electrical disturbance by conduction and coupling
|
|
|

IEC 61000-4-4, (EFT)Burst on power line
|
|
|

IEC 61000-4-4, (EFT) Burst on signal line-capacitive coupling clamp
|
|
|

IEC 61000-4-5, Surge on power line
|
|
|

IEC 61000-4-11, Power fail simulation
|
|
|

IEC 61000-4-8, Power frequency (50Hz) magnetic field
|
|
|

IEC 61000-4-6, Conducted disturbances induced by radio frequency fields, CDN,
EM clamp
|
|
|

SAE J1113-42 Conducted Transient Emissions
|
|
|

European Directive 2004/104/EC
|
| |